Chapter 3 - Previous releases
60 Version 1.6.2a.0 May 17, 2011
Fixed a long standing problem with project linking where "write" controls (from the
perspective of the client) are not always sent to the server when the client first connects or if it
reconnects to the server.
Release 1.2 (March 9, 2006)
Features
General
Added support for ControlMatrix integration via a new ControlMatrix device in the
Control menu. This device is intended for centralized ControlMatrix designs. Some
customization is required for more complex NION arrangements (i.e. multiple projects) or
interoperability with ControlManager. Contact Peavey should you need more assistance.
Support for the custom NioNode SNMP extensions has been moved to the new Peavey
registered namespace:
iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).peavey(24603)
.nion(1).nionode(1)
. SNMP subagent functionality is unchanged. A new MIB
definition reflecting these changes can be found at:
NWare\plugins\pion\doc\PEAVEY-NION-NIONODE-MIB-V2.my.
Added the ability to add SNMP control and monitoring for up to 256 controls per physical
NioNode unit. To add SNMP Flyoffs to the NioNode in the Flyoffs tab, put the total
quantity needed into the 'Number of SNMP exported controls' field of the NioNode
properties dialog. If the quantity is greater than 0, an 'SNMP Exports' tab will be added to
the NioNode device. In the row for each control, there is a 'R/O' button and a Label field.
When 'R/O' is off, the control can be read and set via SNMP. When on, the control is
read-only. Read-only is the default setting. Since the SNMP flyoffs and the
'exportedControlTable' in the MIB keep track of the controls via their "index" number, you
should enter a short description in the label field that will also be viewable in the
exportedControlTable as 'controlLabel'. SNMP flyoffs should only be wired to master
nodes on controls that you want to monitor or control. To provide SNMP control of a
Python script, you should wire a generic control to both the Python script and to the SNMP
flyoff.
Added support for the NIO-AES digital audio IO card.
Added control to enable RS-485 unicast addressing in the CAB's RS-485 tab.
Added filibuster mode to PageMatrix logic device. This enables 'first-come-first-serve'
logic on stations of equal priority. In order for this to work, you must also set priorities
equal on intended station/zone combinations.
'Copy control attributes' now copies polygon shapes as well as general control settings.
The following control operator functions are now multichannel aware - invert, negate,
absolute value, threshold, hysteresis, toggle on rising edge, toggle on falling edge, value
link, position link, and string link.
Changed default low/high pass filter type to Linkwitz-Riley so default crossovers have a
flat frequency response.
Added drop-down list of pages in Launcher dialog box.
Added control ruid and device id to 'Find control' dialog box if a control was selected.
Added string mulitplexer/demultiplexer devices, created for sending a lot of control values
through one wire of the Project Linker devices.
Added the % operator to the expression evaluator. This restarts the sequence after n
iterations. For example "Input {1+=1%4}" would give "Input 1", "Input 2", "Input 3",
"Input 4", "Input 1", "Input 2", "Input 3", "Input 4", etc.