NWare Release Notes
May 17, 2011 Version 1.6.2a.0 11
So
me text t o force a page b reak in Word but remain inv isible
Release 1.6.2 (May 5, 2011)
Live Update
Sometimes, more up-to-date release notes are available online. Click here
(http://www.peaveyoxford.com/Documentation/1.6.2/Release_1.6.2.htm) to download the
latest version from the Peavey Oxford website, then press F5 to refresh the display.
Features
NWare
New Tally plugin
A new Tally plugin has been added in this version. It is located under Plugins / Peavey /
Control / Tools in the device tree. This device allows you to count the number of times a button
is clicked. Help is available via the Info button on the control surface.
NION
New Python libraries now included
The Python string.py and struct.so libraries are now included with this version.
Note: The nControl and nTouch 180++ firmware include a full set of Python libraries.
Enhancements
NWare
Defaults for project properties changed to improve performance
The defaults for new projects have been changed to improve performance on NioNodes. The
control frame rate is now 10 updates per second (changed from 30).
Updates to the NioNode AEC card tab
The AEC card tab has a number of enhancements in this version:
New Adaption Halt button that disables the adaption filter for the channel.
New NLP Threshold setting that specifies the threshold for an Expander device wired to
the AEC Out signal. For more information, see Threshold Level (for Expander device) in
the NWare Device Reference.
New AEC Input Clipping LED that indicates when the input level from the near end reaches an
internally set threshold and is automatically clipped.
Note: When clipping occurs, AEC performance will be impaired.
The Echo Atten meter, which shows the level of attenuation of the echo part of the signal
(Echo Return Loss Enhancement - ERLE), has been updated. The range of the meter is
now -6 dB to +35dB.
The AEC Input Routing Setup page has been removed and the physical inputs on the AEC
card (in.Analog flyoffs) are no longer hardwired to the out.to AEC flyoffs.
For more information on the AEC card control surface, see Slot x: AEC in the NWare Device